08 July 2024

Improving air quality in and around schools

Improving air quality in and around schools image

Megan Bennett, product marketing manager at Nuaire, looks at how poor air quality impacts children both in and getting to and from school, and what steps we can take to improve the air our children breath.

Schools should be a safe place to learn, yet 86% of new schools in England are in areas breaching World Health Organization air pollution limits; that’s 147 schools. Sadly, there is no legal requirement for air pollution to be considered in planning for new schools despite children spending on average 35 hours a week at school for half the year.

How dangerous is air pollution for children?

In the most recent annual air quality assessment, the UK was non-compliant with the annual mean concentration limit value for NOx at a number of roadside locations in urban areas. It is estimated that 65% of the NOx concentrations at the roadside originate as NOx emissions from road transport.

Short-term exposure to concentrations of NOx can cause inflammation of the airways and increase susceptibility to respiratory infections and to allergens. Children are particularly vulnerable because their bodies, organs, and immune systems are still developing. Furthermore, children tend to spend more time outside – including travelling to and from school – so have greater exposure to polluted air.

Expanding our knowledge

Over the years we have come to better understand the harm brought about by exposure to air pollution, even in small amounts. But indoor air quality is very much understudied compared to outdoor air pollution, even though it impacts pupils' health and concentration, affecting attendance and attainment.

Research is ongoing and is necessary if we are to make effective changes. Several studies specific to school environments are underway, including the SAMHE (Schools’ Air quality Monitoring for Health and Education) citizen science project. It is establishing a network of air quality monitors in schools across the UK, to generate an unparalleled dataset which will help researchers better understand schools indoor air quality and will provide evidence for better national policies and practice.

What can be done to improve air quality in and around schools?

Nuaire's BPS range of packaged Air Handling Units (AHUs) are perfect for sports halls.

The expansion of Low Emission Zones (LEZs) in urban areas is one solution being put forward. Despite their controversy, LEZs are effective in reducing air pollution. A study by the University of Bath on London's LEZ implemented in 2008 and ultra low emission zone (ULEZ) introduced in 2019 found particulate matter (PM10) had been reduced by 13% between 2008 and 2013, compared to between 2003 and 2007, and nitrogen dioxide levels had fallen by 18.4% in 2019 compared to the period between 2016 and 2018. This reduction in air pollution contributed to a 4.5% reduction in long-term health problems and an 8% decrease in respiratory issues, helping generate cost savings of more than £963m in Greater London.

Reducing emissions from transport by providing wider access to reliable, affordable and efficient public transport, plus encouraging walking and cycling (and making them safer!) will certainly have a positive impact for external air pollution. But what about indoor air quality? Reducing external air pollution will have a positive impact on internal air quality, but it’s not the entire story.

Education buildings can be some of the most diverse, with most of them having classrooms, kitchens, canteens, halls, gymnasiums and even swimming pools. Indoor air quality varies tremendously not only between schools, but also within them. Effective ventilation solutions must be deployed within schools to provide good indoor air quality that is conducive to learning.

When it comes to classrooms, systems that are powerful enough to ventilate multiple rooms and that come with a filter to remove incoming pollutants, such as the Nuaire XBOXER XBC range, are ideal. These also come with heat recovery, so are energy efficient.

For sports halls, the biggest challenge is CO2 and odours which must be removed. Our BPS range of packaged Air Handling Units (AHUs) are perfect for these environments as they are able to provide a high volume of air movement and do so with high efficiency. To not waste energy through running the unit when the space is not in use, it is good practice to use occupancy sensors and pollutant sensors (such as CO2 sensors) which control when units are active. This will prevent them running when ventilation is not required.

If the school is lucky enough to have an indoor swimming pool, then a ventilation system that can cope with high levels of humidity and corrosive chlorine needs to be specified. Our Boxer Bespoke range of AHUs can be coated for such applications.

Toilets and WCs in schools are high use areas which can fill with indoor air pollutants and odours very quickly if not ventilated correctly. Twin fans technology, originally invented by Nuaire in 1973, is standard practice for areas such as toilets. Duty share of the two fans within the unit means that the fan continues to work in the event of one fan failing.

Twin fans technology, originally invented by Nuaire in 1973, is standard practice for areas such as toilets.

In school kitchens, a bifurcated fan, such as Nuaire’s Squif range, with the motor out of the airstream is a good solution, as it means that pollutants such as grease do not clog up the motor – something that can result in fan failure over time.

Addressing both external air pollution and indoor air quality is vital if we are to provide our children with a safe, comfortable place to learn. No child should have to breath dangerous or stale air just to get an education.

Nuaire has been delivering clean air solutions for over 50 years, setting industry standards in residential, commercial and industrial ventilation systems. For more information go to www.nuaire.co.uk/commercial/education.

This article was sponsored by Nuaire.

SIGN UP
For your free daily news bulletin
Highways jobs

Health Improvement Officer

Sheffield City Council
Grade 7 £37,035 to £40,476
Working within the wider determinants team, this role will be supporting two Public Health Principal leads. Sheffield, South Yorkshire
Recuriter: Sheffield City Council

SEND Inclusion Partner

Essex County Council
£41514.0000 - £48841.0000 per annum
SEND Inclusion PartnerFixed Term up to 12 months, Full Time£41,514 to £48,841 Per AnnumLocation
Recuriter: Essex County Council

Traffic Regulation Order Lead

Royal Borough of Greenwich
£39,951 - £42,840
Royal Greenwich is a borough synonymous with first class modern services. Greenwich, London (Greater)
Recuriter: Royal Borough of Greenwich

Operational Supervisor

Royal Borough of Greenwich
£37,068 - £44,331
An opportunity has arisen for 1 Operational Supervisor (Career Graded) within Street Services. Greenwich, London (Greater)
Recuriter: Royal Borough of Greenwich

Caretaking Team Leader

Royal Borough of Greenwich
£31,524 - £32,931
These posts are for people who like working outdoors and are prepared to work flexibly in Caretaking Services. Greenwich, London (Greater)
Recuriter: Royal Borough of Greenwich
Linkedin Banner

Partner Content

Circular highways is a necessity not an aspiration – and it’s within our grasp

Shell is helping power the journey towards a circular paving industry with Shell Bitumen LT R, a new product for roads that uses plastics destined for landfill as part of the additives to make the bitumen.

Support from Effective Energy Group for Local Authorities to Deliver £430m Sustainable Warmth Funded Energy Efficiency Projects

Effective Energy Group is now offering its support to the 40 Local Authorities who have received a share of the £430m to deliver their projects on the ground by surveying properties and installing measures.

Pay.UK – the next step in Bacs’ evolution

Dougie Belmore explains how one of the main interfaces between you and Bacs is about to change.