The COVID-19 vaccination programme is underway. Once the over 50s, younger people with health conditions, NHS and care workers have received the vaccine, Prime Minister Boris Johnson has been clear that current lockdown restrictions could be lifted in stages, with priority given to schools and getting businesses back to work.

Although the situation is under review, there is an expectation that businesses premises could reopen as early as Easter, when a large proportion of the working age population may not have been vaccinated.

That means the focus in workplaces and multi-occupant spaces, especially those open to the public, must remain on limiting transmission to prevent the spread of coronavirus to un-vaccinated people.

Advice from the Government’s Scientific Advisory Group for Emergencies (SAGE) in its document Role of Ventilation in Controlling SARS-CoV-2 Transmission, is that: 'Ventilation should be integral to the COVID-19 risk mitigation strategy for all multi-occupant public buildings and workplaces.'

The SAGE publication follows the World Health Organisation's acknowledgement last July of the possibility of airborne transmission of coronavirus. This in turn confirmed the lead provided by the Chartered Institution of Building Services Engineers (CIBSE) in its COVID-19 Ventilation Guidance, issued in May, referenced in the SAGE document.

The need for effective ventilation in helping limit the spread of COVID-19 is based on growing evidence that coronavirus can be spread by tiny particles called aerosols.

The acts of breathing, talking, coughing and sneezing all produce droplets and aerosols that may, if the host is infected, contain pathogens. Larger droplets fall by gravity within 2m from the source, which is why social distancing is recommended. The droplets land on surfaces and can therefore get onto hands - hence the importance of regular hand washing and avoiding touching the face. Smaller aerosols, however, can stay airborne for hours, which enables them to travel longer distances where they could infect secondary hosts, particularly in poorly ventilated spaces.

The advice from SAGE, based on modelling, is that 'exposure to aerosols approximately halves when the ventilation rate is doubled'. This is in line with the underlying principle adopted by CIBSE which is: dilute and ultimately remove as many airborne pathogens as possible from a space by exhausting them to the outside to reduce the opportunity for deposition or inhalation.

In practice this means taking steps to increase both the supply of outside air and exhaust ventilation in buildings as much as is reasonably possible while minimising, or eliminating, any recirculated air.

If the ventilation rate in a space is designed, constructed and maintained at current design standards, then SAGE says the risk of aerosol transmission is likely to be low. In most workplaces and public environments, the Advisory Group say this equates to an outside air supply rate of 8-10 l/s/person; which is the minimum outside air supply rate recommended by CIBSE and also satisfies the building and workplace regulations.

Providing effective ventilation is more of a challenge in older buildings, particularly where systems may not have been designed in line with current standards. CIBSE's COVID-19 Ventilation Guidance document provides information to help building owners and operators understand the types of ventilation systems commonly encountered in buildings and how these can best be used to reduce the risks of airborne infection.

Getting the ventilation rate right is a difficult balance. Ventilation has well-established associations with health and has a complex relationship with other factors including energy, noise, air quality and thermal comfort. Those modifying an existing system, or altering its operation, should be mindful of the possibility of unintended consequences of their actions; for some mechanical installations it would be wise to seek expert advice before taking any action.

For naturally ventilated buildings, where a space is reliant on opening windows and doors for ventilation, the advice is that windows and vents should be used more than normal. In warm weather opening windows is a typical response, however it is important windows are kept open, even if only by a small amount, to maintain ventilation when it is cooler outside.

Of course, opening windows can result in draughts and occupant discomfort. An alternative solution to complement background ventilation is to encourage all occupants to take regular breaks simultaneously throughout the day to allow the room to be purged with outside air by opening windows and doors.

Unlike distancing and hand washing, ventilation requirements cannot easily be distilled into one simple approach that everyone can follow. Assessing ventilation in many environments is challenging and will require the type of engineering expertise CIBSE members can provide to ensure any proposed mitigation measures will be effective.

Hywel Davies is technical director of the Chartered Institution of Building Services Engineers (CIBSE)

SIGN UP
For your free daily news bulletin
Highways jobs

Supervisor (Relief) - Christian Head Residential Care Home WMF1081e

Westmorland and Furness Council
£35,745 - £36,648
We are looking for kind, compassionate candidates interested in the opportunity to make a real difference Cumbria
Recuriter: Westmorland and Furness Council

Governance Support Officer

City of York Council
Grade 6 Level 1- 4 (£26,224 to £28,725 per annum) reduced pro rata
Are you super-organised and looking for a part-time, flexible role, working term time only with a mix of office and home working? York, North Yorkshire
Recuriter: City of York Council

Customer Service Representatives

City of York Council
Grade 5 Level 1 - 4 (24,629 - £25,779 pro rata per annum)
Are you an amazing retail, tourism or contact centre worker with excellent customer service skills. York, North Yorkshire
Recuriter: City of York Council

Care Enabler

Rotherham Metropolitan Borough Council
£23,893 pro rata (Pay award pending)
Do you want to help people maintain and increase their independence also have control over their lives? Rotherham, South Yorkshire
Recuriter: Rotherham Metropolitan Borough Council

Programme Manager WMF1082e

Westmorland and Furness Council
£62,273 to £65,017
This is an exciting opportunity to join the Westmorland and Furness Programme Management Office Cumbria / Various
Recuriter: Westmorland and Furness Council
Linkedin Banner

Partner Content

Circular highways is a necessity not an aspiration – and it’s within our grasp

Shell is helping power the journey towards a circular paving industry with Shell Bitumen LT R, a new product for roads that uses plastics destined for landfill as part of the additives to make the bitumen.

Support from Effective Energy Group for Local Authorities to Deliver £430m Sustainable Warmth Funded Energy Efficiency Projects

Effective Energy Group is now offering its support to the 40 Local Authorities who have received a share of the £430m to deliver their projects on the ground by surveying properties and installing measures.

Pay.UK – the next step in Bacs’ evolution

Dougie Belmore explains how one of the main interfaces between you and Bacs is about to change.